新型原子钟发展现状Progress of Novel Atomic Clocks
张首刚;
摘要(Abstract):
结合我国全球卫星导航定位系统的建设和发展需求,介绍了不同类型的新型原子钟研究现状与发展趋势,并简要给出了发展我国原子钟研究的讨论性意见。
关键词(KeyWords): 卫星导航;原子钟;时间频率传递
基金项目(Foundation): 国家973计划资助项目(2005CB724501);; 国家自然科学基金重点资助项目(10834007);; 中国科学院重要方向资助项目(KJCX2-SW-T12)
作者(Author): 张首刚;
Email:
DOI:
参考文献(References):
- [1]王义遒.建立自主完善的时间频率系统是国运所系[J].电讯技术-时间频率技术增刊,2008,48(4):1-17.
- [2]UHRICH P,VALAT D,ABGRALL M.Steering of the French Time Scale TA(F)Towards the LNE-SYRTE Primary Frequency Standards[J].Metrologia,2008,45(6):42-46.
- [3]CHAPELET F,GUENA J,ROVERA G D,et al.Comparisons Between 3 Fountain Clocks at LNE-SYRTE[C]//Proc.Joint 21st EFTF and IEEE Frequency Control Symp(FCS).[S.l.]:[s.n.],2007:467-472.
- [4]ROSENBAND T,HUME D B,SCHMIDT P O,et al.Frequency Ratio of Al+and Hg+Single-ion Optical Clocks;Metrology at the 17th Decimal Place[J].Science,2008,319(5871):1808-1812.
- [5]SCHILIER S,BRESSEL U,ERNSTING I,et al.Development of Optical Lattice Clock for Future Applications in Space[C]//Joint Conference for EFTF-IEEE Frequency Control Symp(FCS).[S.l.]:[s.n.],2009:313.
- [6]LEMONDE P,STERR U,CURTIS A,et al.Optical Clocks for a New Definition of the Second(OCS),A project of the European Metrology Research Programm[C]//Joint conference for EFTF-IEEE Frequency Control Symp(FCS).[S.l.]:[s.n.],2009:320.
- [7]中国科学技术协会.2007-2008天文学学科发展报告[M].北京:中国科学技术出版社,2008:169-194.
- [8]SETH M,FOREMAN K W,HOLMAN D D,et al.Remote Transfer of Ultrastable Frequency References via Fiber Networks[J].Review of Scientific Instrument,2007,78(2):021101-01-25.
- [9]SANTARELLI G,NARBONNEAU F,LOURS M,et al.High Performance Frequency Dissemination for Metrology Applications with Optical Fibers[C]//Proc.Joint 19st EFTF and IEEE Frequency Control Symp(FCS).[S.l.]:[s.n.],2005:925-927.
- [10]AMY-KLEIN,LOPEZ,DAUSSY,et al.High-resolution Optical Frequency Dissemination on A Telecommunication Newwork[C]//Joint Conference for EFTF-IEEE Frequency Control Symp(FCS).[S.l.]:[s.n.],2009:211.
- [11]王义遒.星载原子钟国外的发展概况和我国的发展途径[C]//香山科学会议第181次学术讨论会论文集“卫星导航星载原子钟与同步技术”.北京:[出版者不详],2002:14-55.
- [12]王育竹.新一代空间原子钟研究进展[C]//香山科学会议第181次学术讨论会论文集“卫星导航星载原子钟与同步技术”.北京:[出版者不详],2002:141-147.
- [13]梅刚华.星载铷原子钟关键技术与研究进展[C]//香山科学会议第181次学术讨论会论文集“卫星导航星载原子钟与同步技术”.北京:[出版者不详],2002:86-93.
- [14]张首刚.欧洲空间原子钟发展简介[Z].涉密资料,2004.
- [15]张首刚.关于近期空间原子钟研究项目的建议[Z].涉密资料,2004.
- [16]VANIER J,AUDOIN C.The Quantum Physics of Atomic Frequency Standards[M].Bristol,England:Adam Hilger,1989.
- [17]王义遒,王庆吉,傅济时,等.量子频标原理[M].北京:科学出版社,1986.
- [18]MILETI G,DENG J,WALLS F L,et al.Laser-pumped Rubidium Frequency Standards:New Analysis and Progress[J].IEEE Journal of Quantum Electronics,1998,34:233-237.
- [19]AFFOLDERBACH C,ANDREEVA C,CARTALEVA S,et al.Light-Shift Suppression in Laser Optically Pumped Vapor-cell Atomic Frequency Standards[J].Applied Physics.B,Lasers and Optics,2005,80:841-848.
- [20]AFFOLDERBACH C,MILETI G,DROZ F.Experimental Demonstration of A Compact and High-performance Laser-pumped Rubidium Gas Cell Atomic Frequency Standard[J].IEEE Transactions on Instrumentation and Measurement,2006,55:429-435.
- [21]VANIER J,LEVINE M W,JANSSEN D,et al.The Coherent Population Trapping Passive Frequency Standard[J].IEEE Transactions on Instrumentation and Measurement,2003,52(2):258-262.
- [22]范琦,郭文阁,杜志静,等.相干布居囚禁现象用于原子频标[J].时间频率学报,2006,29(2):107-115.
- [23]郭文阁,范琦,王鑫,等.相干布居囚禁原子钟技术及其进展[J].时间频率学报,2007,30(1):45-52.
- [24]YAN Bo,MA Yi-sheng,WANG Yu-zhu.Atomic Frequency Standards Based on Pulsed Coherent Light Storage[C]//Proc.7th International Symposium on Frequency Standards and Metrology.[S.l.]:[s.n.],2008:329-337.
- [25]ALLEY C O.Coherent Pulse Techniques in the Optical Detection of the 0-0 Ground State Hyperfine Resonance in Rubidium 87[M]//TOWNES C W.Quantum Electronics.New York:Columbia University Press,1960:146-155.
- [26]ARDITI M,CARVER T R.Atomic Clock Using Microwave Pulse-coherent Techniques[J].IEEE Transactions on Instrumentation and Measurement,1964,3(2):146-152.
- [27]LEVI F,NOVERO C,GODONE A,et al.Analysis of the Light Shift Effect in the 87Rb Frequency Standards[J].IEEE Trans.Instrum.Meas,1997,46(2):126-129.
- [28]GODONE A,MICALIZIO S,LEVI F.Pulsed Optically Pumped Frequency Standard[J].Phys.Rev.A,2004,70(2):023409(1-11).
- [29]GODONE A,MICALIZIO S,CALOSSO C E,et al.The Pulsed Rubidium Clock[J].IEEE Transactions on Ultrasonics,Ferroelectrics and Frequency Control,2006,53(3):525-529.
- [30]GODONE A,LEVI F,MICALIZIO S,et al.Frequency-stability Performances of the Pulsed Optically Pumped Rubidium Clock:Recent Results and Future Perspectives[J].IEEE Transactions on Instrumentation and Measurement,2007,56:378-382.
- [31]GODONE A,LEVI F.The Coherent Population Trapping maser[M]//GILL P.Proceeding of the 6th Symposium on Frequency Standards and Metrology.[S.l.]:[s.n.],2001:175-182.
- [32]VANIER J,GODONE A,LEVI F,et al.Atomic Clock Based on Coherent Population Trapping:Basic Theoretical Models and Frequency Stability[C]//Proc.17th EFTF and IEEE Frequency Control Symp(FCS).[S.l.]:[s.n.],2003:2-15.
- [33]CYR N,TETU M,BRETON M.All-optical Microwave Frequency Standard:a Proposal[J].IEEE Transactions on Instrumentation and Measurement,1993,42(2):640-649.
- [34]MICALIZIO S,GODONE A,CALOSSO C,et al.Gas Cell Frequency Standards for Space Application at IEN[C]//Procedding of 1st ESA International Workshop on Optical Clock.[S.l.]:[s.n.],2005:9-16.
- [35]ESNAULT F X,HOLLEVILLE D,GUERANDEL S,et al.Reaching a few 10-13τ-1/2 Stability Level with a Compact Cold Atom Clock[C]//Proc.7th Symposium on Frequency Standards and Metrology.[S.l.]:[s.n.],2008:463-467.